TCP-IP Modbus Tester Download do APK para Android
lang pt

TCP-IP Modbus Tester
TCP-IP Modbus Tester
Download do APK
TCP-IP Modbus Tester

TCP-IP Modbus Tester

Desenvolvedor: Giuseppe CURCIO
Tamanho do App: 165k
Data de Lançamento: Nov 12, 2014
Preço: Free
4.3
13 Avaliações
Tamanho:
165k
Download do APK
Google Play
Capturas de Tela do App
Móvel

About: TCP-IP Modbus Tester

ITA:
Con questa App è possibile collegarsi in Wi-Fi (Wireless Connection) con un dispositivo Server.
Sfruttando la suite TCP/IP, attraverso la porta 502, viene aperto un socket con il device.
E' possibile eseguire la lettura e/o la scrittura di un valore in un registro presente all'interno della mappa dati del dispositivo [zona dati 4x Holding Register].
In questa versione sono stati implementati alcuni essenziali controlli sui parametri necessari all'apertura del socket e all'indirizzo del registro da leggere ed eventuale valore da scrivere.


TCP-IP Modbus Tester


In particolare il risultato della lettura è visualizzato nei tre formati standard: esadecimale, binario e decimale segnato e non segnato.
Function-Code implementati:
FC16d/10h = Write Multiple Holding Registers - richiesta limitata a un solo registro
FC03d/03h = Read Holding Registers - richiesta limitata a un solo registro
Per ciascuna richiesta inviata viene fornito un feed-back di stato

ENG:
With this App you can connect to Wi-Fi (Wireless Connection) with a device server.
Exploiting the TCP / IP suite, through port 502, is open a socket with the device.
It is possible to perform reading and / or writing a value in a register inside the map device data [data zone 4x Holding Register].
In this version have been implemented some basic checks on the parameters necessary to the opening of the socket and the address of the register to be read and possible value to be written.
In particular, the reading result is displayed in three standard sizes: hexadecimal, binary and decimal signed and unsigned.
Function-Code implemented:
FC16d / 10h = Write Multiple Holding Registers - request limited to one register
FC03d / 03h = Read Holding Registers - request limited to one register
For each request comes a feed-back of state
Apps do Desenvolvedor:
Lançamentos Recentes

Reviews TCP/IP Modbus Tester


Avaliações dos usuários
Total de avaliações: 13
Avaliações
4.3
13 Avaliações
5 Estrela
4 Estrela
3 Estrela
2 Estrela
1 Estrela
Name
Message
Whatsapp
Vkontakte
Telegram
Reddit
Pinterest
Linkedin
Ocultar